prima pagina

N.C. GAS SOLENOID VALVES WITH MANUAL RE-SET

GRC ...

click on picture to enlarge

 Path - First page - Products - Gas Solenoid Valves & Accessories - GRC

APPLICATION

Without power they are closed; they have to be re-opened manually and remain open when powered.

For replacement coils please click here.

 

FEATURES

  • Constructed to DIN standards.

  • Protection IP 54.

  • Alluminium body.

  • Working temperature: ­15 ... +60 °C.

  • Mounted with coil axis within 90° of vertical.

      Power supply   Flow rate m3/h(2)  
Code   DN Volt. W P.max(1) mbar 0.5 mbar 1 mbar Data sheet
  filettate  
GRC 815   1/2" 230 V ~ 25 500 2.8 4 G 921
GRC 415   1/2" 24 V~/­ 25 500 2.8 4
GRC 215   1/2" 12 V ~/­ 12 500 2.8 4
 
GRC 820   3/4" 230 V ~ 25 500 5.5 8 G 921
GRC 420   3/4" 24 V ~/­ 25 500 5.5 8
GRC 220   3/4" 12 V ~/­ 12 500 5.5 8
 
GRC 825   1" 230 V ~ 25 500 8.4 12 G 921
GRC 425   1" 24 V ~/­ 25 500 8.4 12
GRC 225   1" 12 V ~/­ 12 500 8.4 12
 
GRC 832   1"1/4 230 V ~ 25 500 14 20 G 921
GRC 432   1"1/4 24 V ~/­ 25 500 14 20
GRC 232   1"1/4 12 V ~/­ 12 500 14 20
 
GRC 840   1"1/2 230 V ~ 25 500 19 27 G 921
GRC 440   1"1/2 24 V ~/­ 25 500 19 27
GRC 240   1"1/2 12 V ~/­ 12 500 19 27
 
GRC 850   2" 230 V ~ 25 500 28 40 G 921
GRC 450   2" 24 V ~/­ 25 500 28 40
GRC 250   2" 12 V ~/­ 12 500 28 40
 
  flangiate  
GRC 865   65 (4 fori) 230 V ~ 25 500 55 80 G 921
GRC 465   65 (4 fori) 24 V ~/­ 25 500 55 80
GRC 265   65 (4 fori) 12 V ~/­ 25 500 55 80
 
GRC 880   80 (8 fori) 230 V ~ 25 500 70 100 G 921
GRC 480   80 (8 fori) 24 V ~/­ 25 500 70 100
GRC 280   80 (8 fori) 12 V ~/­ 25 500 70 100
 
GRC 8100   100 (8 fori) 230 V ~ 45 500 110 155 G 921
GRC 4100   100 (8 fori) 24 V ~/­ 45 500 110 155
GRC 2100   100 (8 fori) 12 V ~/­ 45 500 110 155
  • (1) ­ Maximum working pressure

  • (2) ­ Flow of methane with pressure drop of 0.5 mbar (5mmWG) and 1 mbar (10 mmWG)

  • 100 mbar = 10 kPa = 1,000 mm.WG

PRESSURE DROP GRC

 

FEATURES OF GAS SOLENOID VALVES

Model

Operation

Advantages

Disadvantages

 Normally closed with manual re-set GRC
  • Without power closes.

  • With power opens only by manual action.

  • Maximum safety for all uses.

  • At each failure of mains supply, valve closes.

  • When power returns valve has to be re-opened manually.

  • Not suitable for kitchens because, if no power, user tends to re-open valve with mechanical aids.

  • On return of power, safety system no longer functions.